| common
mode chokes |
| RL-1361 |
| Renco Common Mode Chokes
are designed to help meet U.S. and International requirements
for safety and EMI. By placing these chokes at the
inputs of electrical equipment or circuits EMI feedback
can be kept within specified limits. These low priced
Common Mode Chokes are available in a wide range of
standard inductances and current ratings from 100mA
to 5.5Amps. The PC mounting makes them easy to incorporate
in equipment. |
| Applications: |
| Under normal operating
conditions, power supplied through the Common Mode
Choke is balanced. When the equipment in which the
choke is utilized generates electrical noise due to
operation of relays, triacs, SCRs, etc., these transient
noise pulses cause an imbalance in the power line current.
Since the coils of the Common Mode Choke are out of
phase with each other, noise being fed back to the
power level and does not interfere with other equipment
operating on the same power line. |
| special
features: |
• Low
Profile
• Varnish Impregnated
• MTL Used Class B 130°C
• Nonlisted Values Available
• MIL Spec. and Encapsulation Available |
| specifications: |
• Windings
balanced within 1%
• @+80°C ambient, +40°C rise
• -55°C to +130°C operating temperature
• 2000 VAC Hipot winding to winding
• 1500 VAC Hipot winding to core
• All specifications measured @ +20°C
• Inductance values: ±25% @ 1KHz |
|